Détecteur de fumée interconnecté sans fil, 10 ans (pile scellée)

· Technologie de capteur à spectre divisé
· Fonctions de test et de silence sur un seul bouton
· Sortie sonore forte supérieure à 85 dB(A) à 3 mètres
· Faible consommation de courant de repos
· Conception de circuits imprimés pour dispositifs à montage en surface (SMD)
· Signal d'avertissement de batterie faible
· Batterie intégrée, installation facile
· Mis au silence par une télécommande infrarouge fonctionnelle
· Sans fil interconnecté avec un maximum de 24 appareils
· Numéro SKU : DHI-HY-SA30A-R8
£28.56 Prix régulier
Prix unitaire  par 
BUY MORE
SAVE MORE
QuantityUnit Price
2£22.8
5£21.6
More than 5Unlock distributor price

Free Shipping

Quick Delivery

Quality Guarantee

EU Warehouse

Description

Specifications

Specifications

Model

DHI-HY-SA30A-R8

Collection Type

Smoke

Sampling Period

9s

Alarm Volume

85dB (A) at 3 m (9.84 ft)

Silence Duration

12 min

Pre-Set Alarm Value

0.2dB/m-0.3dB/m

Operating Frequency

868 MHz

Radio Signal Range

Up to 1000 m (3280.84 ft) in open air

Power Source

3V CR123A lithium battery (non-replaceable)

Operating Temperature

-10°C to +55°C (+14°F to +131°F)

Operating Humidity

≤ 95% RH (non condensing)

Dimensions

φ98 mm × H43.1 mm (φ3.85" × H1.70")

Weight

138 g (0.30 lb)

Installation

Ceiling Mount

Certifications

TÜV and CE listed

Compliance Standard

EN 14604:2005+AC:2008

FAQ

FAQ

How long will I receive the parcel?

Generally speaking, the order processing time is 1-3 working days, and the logistics transportation time is 1-5 working days.

Why smoke alarm beeping when there is no smoke?

To know why the smoke alarm beeps, let's get to know when it alarms. The smoke alarm usually alarms for these 3 situations: when there is a smoke, and it alarms when the smoke level reaches the value; secondly it might be a fault alarm when there is a bug or some dust wents in; thirdly it will also alarms when it's low battery warning. So how can we get to know why it alarms? You can also judge by the LED indicator that tells you the real reason. When the Green indicator flashes once perminute it means it's standby. When the Red indicator flashes once per second it means it has detected the smoke and alarming. When the Red indicator flashes once per minute means the smoke alarm is in fault. When the Red indicator flashesonce per minute that means the smoke alarm is already Low battery. You need to change it.

How can I stop a false alarm?

It's crucial to approach an alert signal as a potentially hazardous circumstance. By hitting the Test/Silence button during a known false alarm, you can temporarily mute your device for 12 minutes. Also, you can use a normally working infrared remote and press any button on it to mute a known false alarm. We advise cleaning the device with the soft brush attachment for your vacuum cleaner on a regular basis as part of normal maintenance to prevent false alerts.

How many smoke alarms do I need for home?

For home use, when the height of the space is less than 8m (3.28 ft), the protection area of a device is20 m2–40 m2. So you can judge how many smoke alarms according to how many bedrooms and the area for your home.
Package List
Interlinked Smoke Alarm
Self-tapping Screw
Extension Blot
Positioning Sticker
User's Manual