Welkom bij de Wisualarm online winkel

5pc interlinked smoke alarms
Wisualarm smoke alarm meets regulation
Wisualarm smoke alarm easy to install
smoke alarm clean design
split-spectrum technology
  • Afbeelding in Gallery-weergave laden, 5pc interlinked smoke alarms
  • Afbeelding in Gallery-weergave laden, Wisualarm smoke alarm meets regulation
  • Afbeelding in Gallery-weergave laden, Wisualarm smoke alarm easy to install
  • Afbeelding in Gallery-weergave laden, smoke alarm clean design
  • Afbeelding in Gallery-weergave laden, split-spectrum technology

5PC Wisualarm Interlinked Smoke Alarms

  • 10 years battery lifetime and 5 years warranty
  • Connect up to 24 devices
  • 3V CR123A lithium battery (non-replaceable)
  • Compliance Standard: EN 14604
  • Model: DHI-HY-SA30A-R8-5
  • Certifications: CE logo UKCA_LOGO

£79.99 Normale prijs £102.99 Aanbiedingsprijs
Eenheidsprijs  per 

Safe Payment

Quick Delivery

Security & Privacy

UK Warehouse

Description

Specification

Specification

Product Interlinked Smoke Alarm
Battery Life 10 Years
Collection Type Smoke
Sensor Type Photoelectric
Alarm Mode Visual and audible alarm
Power Source 3V CR123A lithium battery (non-replaceable)
Operating Current Monitoring current: ≤ 15uA (avg.) Alarm current: ≤ 25mA (avg.)
Operating Temperature -10°C to +55°C (+14°F to +131°F)
Operating Humidity ≤ 95% RH (non condensing)
Maximum Number ofInterconnected Units 24 pcs
Radio Signal Range Up to 1000 m (3280.84 ft) in open air
Up to 1000 m (3280.84 ft) in open air Support

FAQ

FAQ

How long will I receive the parcel?

Generally speaking, the order processing time is 1-3 working days, and the logistics transportation time is 1-5 working days.

Why smoke alarm beeping when there is no smoke?

To know why the smoke alarm beeps, let's get to know when it alarms. The smoke alarm usually alarms for these 3 situations: when there is a smoke, and it alarms when the smoke level reaches the value; secondly it might be a fault alarm when there is a bug or some dust wents in; thirdly it will also alarms when it's low battery warning. So how can we get to know why it alarms? You can also judge by the LED indicator that tells you the real reason. When the Green indicator flashes once perminute it means it's standby. When the Red indicator flashes once per second it means it has detected the smoke and alarming. When the Red indicator flashes once per minute means the smoke alarm is in fault. When the Red indicator flashesonce per minute that means the smoke alarm is already Low battery. You need to change it.

How can I stop a false alarm?

It's crucial to approach an alert signal as a potentially hazardous circumstance. By hitting the Test/Silence button during a known false alarm, you can temporarily mute your device for 12 minutes. Also, you can use a normally working infrared remote and press any button on it to mute a known false alarm. We advise cleaning the device with the soft brush attachment for your vacuum cleaner on a regular basis as part of normal maintenance to prevent false alerts.

How many smoke alarms do I need for home?

For home use, when the height of the space is less than 8m (3.28 ft), the protection area of a device is20 m2–40 m2. So you can judge how many smoke alarms according to how many bedrooms and the area for your home.
Single Item Package List
Interlinked Smoke Alarm
Self-tapping Screw
Extension Blot
Positioning Sticker
User's Manual

Reviews From Amazon

Reviews From Amazon

Kan ik u helpen of wilt u deskundig advies?